Description: Description:Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.Features:8 inch TFT color screenExquisite design suitable to moving operation Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.Real-time S-T segment analysis, pace-maker detection. Built-in rechargeable lithium battery, convenient for patient moving. Suitable for adult, pediatric and neonatal patientStandard Configuration:SpO2, PR, NIBP, ECG, RESP, TEMPTechnical Parameters:ECG:Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection:I, II, III, avR, avL, avF, V,Waveform:2 chGain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mVHeart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)Accuracy:± 1% or ± 1bpm,which greatResolution:1 bpmST measurement Range:-2.0-+2.0mVSweep Speed:12.5 mm/s,25mm/s,50mm/sAlarm:AvailableReview:AvailableRESP:Method Impedance between R-F(RA-LL)Measuring Range:Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpmResolution:1 rpmAccuracy:±2 rpmNIBP:Method:OscillometricMode:Manual, Auto, STATMeasuring and alarm range Adult ModeSYS:40 ~ 270 mmHgDIA:10 ~ 215 mmHgMEAN:20 ~ 235 mmHgPediatric ModeSYS:40 ~ 200 mmHgDIA:10 ~ 150 mmHgMEAN:20 ~ 165 mmHgNeonatal ModeSYS:40 ~ 135 mmHgDIA:10 ~ 100 mmHgMEAN:20 ~ 110 mmHgResolution:1mmHgAccuracy:+-5mmHgSpO2:Measuring Range:0 ~ 100 %Alarm Range:0 ~ 100 %Resolution:1 %Accuracy:70% ~ 100% ±2 %Actualization interval:about 1 Sec.Alarm Delay:10 Sec.Pulse Rate :0~254bpmResolution:1bpmAccuracy:±2bpmTemperature:Measuring and Alarm Range:0 ~ 50 CResolution:0.1CAccuracy:0.1CActualization interval:about 1 Sec.Average Time Constant:< 10 Sec.Package List:Patient monitorTemperature probeECG lead cableECG electrodeAdult NIBP cuffNIBP extension tubeAdult fingertip SpO2 probePower cordUser Manual FDA Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. This item has been cleaned and treated according to the manufacturer's instructions.Crystal-China-Beijing-86-15140779313 The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606. The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989 The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353 The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973 massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
Price: 398.97 USD
Location: Cranbury, New Jersey
End Time: 2024-12-01T07:42:00.000Z
Shipping Cost: 10 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Carejoy
Accuracy: ± 1% or ± 1bpm,which great
Measuring Range: Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
Technology: Digital
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Measuring and Alarm Range: 0 ~ 50 C
MPN: Does Not Apply
Method: Oscillometric
Monitor Parameters: Blood Pressure - NIBP, ECG
Intended Use/Discipline: Medical Laboratory